IP PBX Manual Appendix 8 Software Upgrade
Revision as of 17:41, 2 August 2012 by Paul Falanga (talk | contribs) (Created page with "'''Appendix 8: Software Upgrade''' '''Checking for Upgrade Availability''' # Log into the PBX # Navigate to PBX Setup=>Services and note the firmware version. If the ...")
Appendix 8: Software Upgrade
Checking for Upgrade Availability
- Log into the PBX
- Navigate to PBX Setup=>Services and note the firmware version. If the PBX firmware is earlier than 3.x-xxxx then your system requires a Hard Drive upgrade before you will be able to load any 3.x firmware onto the system. Please contact your IPitomy Sales Representative if an HD upgrade is needed; otherwise continue with the steps laid out in this guide.
System Backup
- Go to PBX Setup=>Database
- Click Backup to create a backup of the current database
- Find the most recent backup and click the Down action arrow to download this database to your computer
Downloading the Firmware File
- In a web browser, navigate to http://www.ipitomy.com/pbx_files/ip1500/
- Download the Current Release
Loading the Firmware File
- Log into the PBX and navigate to PBX Setup=>Services
- Scroll down to the File System panel
- Click Browse and find the current firmware file ipitomy_pbx_<build#>-uf.tgz
- Click Load File to begin the upgrade process
- Depending on your starting firmware version, one of two things will occur:
- A dialog box will pop up announcing that the PBX will reboot, click OK and wait 5 minutes. After the 5 minutes has passed, log out of the PBX, then log back into the PBX (you should see a message when logging in that the Database does not match and will be converted)
- A progress bar will appear while the PBX upgrades and reboots, after which you will be returned to the login screen.
- Log into the PBX and a message will display stating the Database version does not match. Click OK and the DB will update.
- Click Apply Changes
Restoring Backups (Does not need to be done if you want to use the same DB as was previously running on the system)
- Navigate to PBX Setup=>Database
- Find the backup you wish to load and click the curved arrow to restore it as the active database.
- Once the Database loads, Click Apply Changes.
- Navigate to PBXSetup->Services and Click "Restart All Services"
For systems with Digium© Analog Cards/T1/PRI Cards or Xorcom© USB Devices
- If your system has any of these products installed, navigate to Providers=>Hardware Providers
- Scroll down to the Hardware Functions panel
- Click Restart USB Devices & PBX Services