Difference between revisions of "RAID"

From IPitomy Wiki
Jump to navigation Jump to search
Line 115: Line 115:
 
#Replace the HDD.
 
#Replace the HDD.
 
#It is best to match the HDD that is being replaced. If this is not possible, get a replacement HDD with similar specifications and storage capacity. You must match or exceed the storage capacity to assure capacity is available for RAID storage. RAID will configure the media installed to the extent of the smallest capacity HDD. <b> Use a new drive.</b> A drive from another source—particularly another RAID-enabled system may be recognized as the data SOURCE! You could lose all existing data!
 
#It is best to match the HDD that is being replaced. If this is not possible, get a replacement HDD with similar specifications and storage capacity. You must match or exceed the storage capacity to assure capacity is available for RAID storage. RAID will configure the media installed to the extent of the smallest capacity HDD. <b> Use a new drive.</b> A drive from another source—particularly another RAID-enabled system may be recognized as the data SOURCE! You could lose all existing data!
#Continue to: Hardware RAID Restore Procedure.
+
#Continue to: RAID Restore Procedure.
 
<b>USE A NEW DRIVE AS REPLACEMENT</b>
 
<b>USE A NEW DRIVE AS REPLACEMENT</b>
  

Revision as of 18:55, 21 May 2013

Description

IPitomy now delivers RAID-1 on all platforms of the IPitomy IP PBX.RAID is “Redundant Array of Independent Disks”. RAID-1 is the mirroring of data onto two or more independent Hard Disk Drives. (HDD-Array) (Two HDD’s maximum in IP1100 and IP1200.)

Hospitals, Call Support Centers and any organization that strives to provide the highest level of customer service and shave-off possible down-time will find RAID indispensible.

IPitomy RAID is available in software and hardware variations to allow its deployment onto the smallest system configuration.

Software RAID can be implemented on any platform and delivers the basis of RAID security. RAID status is presented to the user/dealer via the Standard IPitomy software interface.

Hardware RAID can be implemented only on the IP2000 and above since it includes a Hard Disk Drive Array controller board. Hardware RAID now includes Hot Swap operation. Swapping-out the defective drive is possible during runtime with the Front Panel access without opening the chassis! The utility SW resides on the PBX in the software level between the hardware interface BIOS and application layers.  HW RAID is recommended for all larger system applications.

RAID is configured at IPitomy and shipped as a complete product solution. It is not available as a field upgrade.

 

RAID related Features IP1100 IP1200 IP2000 IP5000
Mirroring Hard Disks (2x) RAID RAID RAID RAID
Automatic Redundancy RAID RAID RAID RAID
Hot Swappaple Hard Drive No No Yes Yes
Front Panel Hard Drive Access No No Yes Yes
Dual Power Supply No No Yes Yes


RAID Configurations / Redundancy Options

Product Description Part Number
RAID

Add software RAID for Redundant Hard Drive mirroring.  If one drive fails, the other takes over automatically reducing downtime due to drive failure and ensuring a more reliable performance.

SW-RAID
Redundant Power Supply

4U power supply for IP2000/5000 with two independent replaceable hot swappable power supplies contained in one unit.
PRODUCT TECHNICAL SPECIFICATIONS

  • Hot-Swap: This means when either one of the redundant power supply fails or  breaks down, you can easily replace failed unit without any interference to the system.
  •  Buzzer: A warning buzzer sounds when any one of the power supplies fails. 
  • LED’s: Tells if one of the two power supplies has failed by LED blink
REDPS
SATA Front Loading Rack

Front Cabinet Accessible Mobile Rack for SATA Drives - Add to IP2000 Chassis as an Option. Should order 2 units for both mirrored SATA drives so both drives will be accessible. This is only an option on the IP2000 chassis.  This unit is included in the IP5000 and IP2000-E Chassis

KF-91


Procedure

Since the RAID options are installed at IPitomy no user servicing is required to install RAID.This procedure guides the service technician through restoring a system to RAID protected status when a Degraded Array (failure) has occurred.(In RAID-1 data is stored on multiple drives (an Array) as a single drive.)

Raidprocedure1.png


In the screen shot the PBX is reporting:  

“RAID Status: OK”.

This screen capture is from: PBX Setup/Services/





RAID - Drive Removal - Hot Swap

  1. When a failure occurs the displayed information will show which drive has failed.
RaidPicture2.png
  1. If your PBX is equipped with HOT Swap (SATA Front-Loading HD access)… it will be very easy to replace the bad drive.
  2. In the screen example (from PBX Setup/Services) the failed Array drive is indicated. In this case it is Drive 0.
    Note: Be sure to pull the correct (failed) drive as pulling the goo drive will interrupt service!
  3. Locate the defective drive in the PBX.
  4. TAKE Care to remove the correct drive! Using the System Information screen(PBX Setup/Services/)... IDENTIFY the failed drive. In the display the left-most drive is Drive 0, the Center or Right displayed drive is Drive 1. If there are three drives, the right-most drive is Drive 2.
  5. With HOT SWAP just find the key for the Front Panel door. Behind it are two or three HDD’s.
  6. Open the Front Panel door . The top-most drive is Drive 0. The Center or bottom drive is Drive 1 and if there are three HDD’s the bottom-most drive is Drive 2.
  7. Based on the failed drive information turn the key-release of that drive and lift the securing handle. This will gently and safely disengage the drive from the connector buss
  8. Once removed you’ll find that the Front Loader is a carrier assembly and the actual HDD is mounted inside of that carrier. Remove the original—defective HDD.
  9. Replace the HDD.
  10. It is best to match the HDD that is being replaced. If this is not possible, get a replacement HDD with similar specifications and storage capacity. You must match or exceed the storage capacity to assure capacity is available for RAID storage. RAID will configure the media installed to the extent of the smallest capacity HDD. Use a new drive. A drive from another source—particularly another RAID-enabled system may be recognized as the data SOURCE! You could lose all existing data!
  11. Continue to: RAID Restore Procedure.

USE A NEW DRIVE AS REPLACEMENT

RAID - Drive Removal - Withouth Hot Swap

RaidPicture2.png
  1. When a failure occurs the displayed information will show which drive has failed. In this case the failed Array drive is Drive 0.
  2. If your PBX is NOT equipped with HOT Swap you must open the PBX and replace the HDD. Be sure to allocate enough time to perform this task since the PBX will be off-line and powered-down for the procedure.
  3. POWER OFF the PBX; this is most efficiently accomplished using the momentary switch on the front panel. Open the key panel door and locate the rocker switch. It’s a momentary switch and will return to its idle position.
  4. Press this button on the raised side—it may also be printed with a dot or large “I”.
  5. Once pressed the PBX will begin it’s power-down sequence. When this is complete the system running LED will be OFF.
  6. At this time you should be wearing a grounded wrist-strap to prevent ESD damage to components inside the PBX.
    Note: If your system power supply has an On/Off switch, put it in the OFF position
  7. Not all power supplies are the same. If your power supply has an ON/OFF switch, move it to the OFF position. Go to step 8.
  8. Disconnect the power cord at the back of the PBX cabinet where it enters.
  9. Remove the housing cover screws—depending upon the genre of case these vary in location. Usually the case screws are at the sides of the case lid.
  10. The case lid must be pushed backward to free it from the front panel mated-lip. Do so and lift the case lid up and off of the housing.
  11. Inside the PBX, locate the HDD that will be replaced using the next few steps to identify the drive.
  12. Hardware RAID includes a controller board to which the HDD’s are connected. Locate this board, it’s the one with the SATA wires connected from the HDD’s.
  13. Matching the actual HDD to that in the PBX Setup/Services displayed is done by tracing the wire from the corresponding port to the HDD. Some versions of PBX software will also indicate the HDD serial number.
RAIDPicture3.png
  1. In the photo to the right, the HDD connectors on the RAID board are labeled to assist in this identification.
  2. The SATA connector closest to the RAID board is SATA 1 and the connector furthest from the board is SATA 0 (notice the labels applied to the photo.)
  3. Using the wire connected to the SATA port associated to the defective HDD, locate the drive that is to be removed.
  4. Disconnect the SATA cable and power cable from the HDD.
  5. Use standard PC hardware tools to remove the HDD from the chassis.
  6. Replace the HDD. It is best to match the HDD that is being replaced. If this is not possible, get a replacement HDD with similar specifications and storage capacity. You must match or exceed the storage capacity to assure capacity is available for RAID storage. RAID will configure the media installed to the extent of the smallest capacity HDD. Use a new drive. A drive from another source—particularly another RAID-enabled system may be recognized as the data SOURCE! This can result in complete loss of existing data!
    USE A NEW DRIVE AS REPLACEMENT
  7. Install the new HDD using the hardware supplied with the drive.
  8. Connect the SATA cable and power cable to the drive.
  9. Use cable ties and secure the wiring so that it cannot become pinched when the chassis cover is replaced. Also assure that wiring does not obstruct fan blades.
  10. Replace the chassis lid making sure to position the front edge under the housing front mated lip ad secure with the screws previously removed.
  11. Continue to: RAID Restore Procedure.

RAID - Restore

RAIDPicture4small.png
RAIDPicture5small.png
RAIDPicture6small.png




When the HDD has been replaced the RAID Array must be rebuilt so that RAID redundancy is restored. The steps here assume that the HDD has been replaced. If not, return to the previous Procedures to replace the defective drive, then return here to restore RAID functionality. This procedure requires the use of an ancillary (spare) Keyboard and monitor.

  1. With the new HDD installed and the chassis case closed, restore power to the PBX.
  2. Reconnect the power cable to the PBX Chassis power supply.
  3. Not all power supplies are the same. If your PBX PS has an On/Off switch, move it to the ON position.
  4. An ancillary (spare) keyboard and monitor must be connected to the PBX.
  5. Locate the Keyboard and monitor connectors on the PBX chassis.
  6. Connect a PS-2-type keyboard and VGA monitor to the corresponding connectors on the PBX.
  7. Now the PBX can be booted.
  8. Use the Boot-Up/Power-Down button on the front panel to start the boot-up.
  9. Press this button on the raised side, it may also be printed with a dot or large “I”.
  1. Watch the monitor closely during the boot-up sequence. There is only about a three-second window wherein Alt-3 MUST be pressed to start the RAID—layer software.
  2. If you miss this screen allow the PBX to fully boot-up and then use the same Boot-Up/Power-Down switch to Power Down the PBX and then repeat steps from Step 8.
  3. The RAID-layer software utility will start and you should see a screen similar to the one at the top right.
  4. Press Any Key to Continue.
  5. The next screen will indicate the Degraded drive in the Array. There will only ever be one Array in the IPitomy PBX… it is labeled “Array Unit 0”. Notice that there are two HDD’s listed in this Array. The HDD identifications are listed below the Array header. Notice “Port 0” and “Port 1” are listed for Array Unit 0. These numbers correspond to the displayed HDD’s in the PBX interface software (PBX Setup/Services/).
  6. In this example, HDD “0” was the failed drive. Since it has been replaced the new HDD is listed here as “Not in Use”.
  7. Use the arrow buttons on the keyboard to move to and select the Array. (There is only one.)
  8. Press Space bar to select this Array. (An asterisk will appear adjacent to the array title.)
  9. Now use the Tab button to select “Rebuild Array”.
  10. Press Enter.
  11. The option; “Continue on source error:” appears. We suggest you leave this as “disable”.
  12. Position the cursor on “OK” and press Enter.
  13. The last confirmation window appears. Press “Y” (yes) to confirm that the array is to be rebuilt.
  14. Press “F8” to start the process.
  15. Following this the PBX will reboot. Depending on PBX activity and HDD size and source content the time required to rebuild the Array will vary. Fortunately you don’t have to wait… this process will continue in the background while the PBX is running.
  16. Go to PBX Setup/Services/ to view the progress of the rebuild.

(Be patient the process can take 2 hours.)