#If you see HDLC Abort of Primary D-Chan, you most likely have a timing slip on the PRI.  Replacing the cat-5 the provider usually uses with T1 individually shielded pair wiring often times helps with this, as well as potential echo on the lines.
 
#If you see HDLC Abort of Primary D-Chan, you most likely have a timing slip on the PRI.  Replacing the cat-5 the provider usually uses with T1 individually shielded pair wiring often times helps with this, as well as potential echo on the lines.
  
===Echo===
+
=== Echo ===
 +
 
 
If you are experiencing echo on your PRI lines, here are a few things you can try modifying:
 
If you are experiencing echo on your PRI lines, here are a few things you can try modifying:
  
*LBO - By default LBO is set to 0. We have found its a good idea to try -7.5. If this does not work, contact the provider and see if they can tell you how far the dmark is and what to set the LBO to. If none of the settings work, set it back to 0.
+
*LBO - By default LBO is set to 0. We have found its a good idea to try -7.5. If this does not work, contact the provider and see if they can tell you how far the dmark is and what to set the LBO to. If none of the settings work, set it back to 0.
  
*Cabling - Most of the time the provider will install the PRI with cat5 cabling. While this can work, we have found that installing T-1 Cabling (individually shielded pairs) has in the past alleviated echo issues. The reason why is that cat-5 is not really rated to push the voltage needed for a PRI, and without the pairs being shielded themselves, bleed over is possible.
+
*Cabling - Most of the time the provider will install the PRI with cat5 cabling. While this can work, we have found that installing T-1 Cabling (individually shielded pairs) has in the past alleviated echo issues. The reason why is that cat-5 is not really rated to push the voltage needed for a PRI, and without the pairs being shielded themselves, bleed over is possible.  You can overcome the shielding issues by running it as two CAT-5 cables.
  
 
*Echo Cancel Algorithm - Changing this from MG2 to OSLEC has helped eliminate echo in certain installs.
 
*Echo Cancel Algorithm - Changing this from MG2 to OSLEC has helped eliminate echo in certain installs.

Revision as of 19:19, 30 June 2014

Headline text

Multi Port/Card PRI Configuration

When configuring Mutliple PRI Cards or one card with Multiple ports, its important to know the following.

  • D Channel is Always 24
  • Multiple Port cards increment the start and end channel. So you'd make a channel group for 1-23, then a channel group for 25-47, and so on.
  • Channel numbering starts over when you have a second card. So you'd start over with a channel group for 1-23 for the second card.
  • Timing increments as you go along on the same card. Span 1 would be timing 1, span 2 would be timing 2, etc.

Troubleshooting a PRI

  1. Always be sure to check that the settings for the card match what the provider wants. (Switch type is a big one).
  2. If you see HDLC Abort of Primary D-Chan, you most likely have a timing slip on the PRI. Replacing the cat-5 the provider usually uses with T1 individually shielded pair wiring often times helps with this, as well as potential echo on the lines.

Echo

If you are experiencing echo on your PRI lines, here are a few things you can try modifying:

  • LBO - By default LBO is set to 0. We have found its a good idea to try -7.5. If this does not work, contact the provider and see if they can tell you how far the dmark is and what to set the LBO to. If none of the settings work, set it back to 0.
  • Cabling - Most of the time the provider will install the PRI with cat5 cabling. While this can work, we have found that installing T-1 Cabling (individually shielded pairs) has in the past alleviated echo issues. The reason why is that cat-5 is not really rated to push the voltage needed for a PRI, and without the pairs being shielded themselves, bleed over is possible.  You can overcome the shielding issues by running it as two CAT-5 cables.
  • Echo Cancel Algorithm - Changing this from MG2 to OSLEC has helped eliminate echo in certain installs.
  • Echo Training - Increasing this from the default 800 to 1200 has eliminated echo on installs in the past.

Caller ID

If you have no or partial caller id - change answer after to two seconds. To do this navigate to the Channel Group settings and in the field titled "Answer After" set this to two seconds.

If you have no Caller ID, make sure in the Channel Group parameters, you have Use CID set to yes, and also in the Inbound Caller ID field set this value to asreceived .